Skip to main content

Table 3 Summary of model performance results by process stream location and spectral range used in modeling

From: Rapid measurement of soluble xylo-oligomers using near-infrared spectroscopy (NIRS) and multivariate statistics: calibration model development and practical approaches to model optimization

Performance parameter

XOS (g/L)

Total solids (g/L)

Early/waste stream sampling locations

Late stream sampling locations

Early/waste stream sampling locations

Late stream sampling locations

1350–2500 nm

2100–2450 nm

1350–2500 nm

2100–2450 nm

1350–2500 nm

2100–2450 nm

1350–2500 nm

2100–2450 nm

Training

R2

0.97

0.96

1.00

1.00

0.99

0.99

1.00

1.00

RMSEC

0.24

0.28

4.17

3.76

0.30

0.22*

3.72

4.52

Cross validation

R2

0.46

0.71

0.99

1.00

0.46

0.76*

1.00

1.00

RMSECV

1.16

0.78*

4.70

4.08

2.26

1.37*

4.08

4.88

Independent validation

R2

0.52

0.60

0.99

0.99

0.69

0.66

0.99

0.99

RMSEP

0.67

0.63

4.81

4.98

0.97

1.07

5.02

5.86

  1. Results are shown for prediction of XOS concentration (g/L) and total solids concentration (g/L). Reducing the spectral range used in the model to 2100-2450nm does not substantially affect the quality of either the XOS concentration or the total solids concentration models. Asterisks (*) indicate statistically significant differences in truncated-range model compared to corresponding full-range model